ADTRAN Network Card 3010 NTU 8 User Manual

®
Total Access 3000/3010  
NTU-8 Single Fiber Quad E1  
Installation and Maintenance Practice  
Document Number: 61182301E1-5A  
January 2008  
 
Revision History  
Revision  
Date  
Description  
A
January 2008  
Initial release  
Conventions  
The following typographical conventions are used in this document:  
This font indicates a cross-reference link.  
This font indicates screen menus, fields, and parameters.  
THIS FONT indicates keyboard keys (ENTER, ESC, ALT). Keys that are to be pressed simultaneously  
are shown with a plus sign (ALT+X indicates that the ALT key and X key should be pressed at the  
same time).  
This font indicates references to other documentation and is also used for emphasis.  
This font indicates on-screen messages and prompts.  
This font indicates text to be typed exactly as shown.  
This font indicates silk-screen labels or other system label items.  
This font is used for strong emphasis.  
NOTE  
Notes inform the user of additional, but essential, information or  
features.  
CAUTION  
Cautions inform the user of potential damage, malfunction, or  
disruption to equipment, software, or environment.  
WARNING  
Warnings inform the user of potential bodily pain, injury, or death.  
61182301E1-5A  
iii  
 
Total Access 3000/3010 NTU-8 Single Fiber Quad E1 Installation and Maintenance Practice  
Training  
ADTRAN offers training courses on our products. These courses include overviews on product  
features and functions while covering applications of ADTRAN product lines. ADTRAN  
provides a variety of training options, including customized training and courses taught at our  
facilities or at customer sites.  
For inquiries concerning training, contact ADTRAN:  
Training Phone:  
Training Fax:  
800-615-1176, ext. 6996  
256-963-6217  
Training Email:  
iv  
61182301E1-5A  
 
Contents  
Figures  
61182301E1-5A  
v
 
Total Access 3000/3010  
NTU-8 Single Fiber Quad E1  
GENERAL  
This document is an installation and maintenance guide for the Total Access® 3000/3010  
NTU-8 Single Fiber Quad E1 with Ethernet and Performance Monitoring (NTU-8F). Figure 1  
illustrates the NTU-8F (P/N 1182301E1) front panel.  
Figure 1. NTU-8F Front Panel  
DESCRIPTION  
The NTU-8F is a standalone remote network terminal unit that provides for transport four,  
short-haul E1 (G.703) channels, and a 10Base-T or 100Base-T (10/100) Ethernet interface  
that can be multiplexed over a single-mode fiber optic cable to a Total Access 3000/3010 LTU-  
8 Single Fiber Quad E1 with Ethernet and Performance Monitoring (P/N 1182300E1). The  
LTU-8 is located in the Central Office. The NTU-8F is provisionable remotely from the LTU-8.  
Provisioning can be viewed locally and flash upgrades can be initiated by using a VT100 craft  
interface.  
Features  
The basic features of the Total Access 3000/3010 NTU-8F include the following:  
• E1 Status for all channels  
• Loopback Status  
• Optical port status  
61182301E1-5A  
1
 
       
Total Access 3000/3010 NTU-8 Single Fiber Quad E1 Installation and Maintenance Practice  
• Operation over extended temperature range of –5°C to +55°C  
• Optical interface consisting of a single mode transceiver module comprised of a single fiber  
transmitter and an SC connector  
• Optical interface port support for flat SC-type optical connectors  
• Single fiber optical interface  
• Operating wavelengths of 1310 nm and 1550 nm for both receiver and transmitter  
Compliance  
The NTU-8F is compliant with UL 60950 and IEC-60825 Class 1. The NTU-8F is also  
compliant with 21CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice  
No. 50, dated July 26, 2001. The NTU-8F is intended for use in restricted access locations  
only. Table 1 shows the compliance codes for the NTU-8F.  
Table 1. Compliance Codes  
Code  
Input  
Output  
Power Code (PC)  
F
C
Telecommunication Code (TC)  
Installation Code (IC)  
A
The G.703 interfaces for the NTU-8 Single Fiber Quad E1 are to be connected to intra-building  
wiring only.  
The LTU-8 is designed to meet the following environmental classes:  
• ETSI EN 300 019-1-1 “Classification of environmental conditions; Storage,” Class 019-1-1,  
Class 1.2  
• ETSI EN 300 019-1-2 “Classification of environmental conditions; Transportation,” Class  
019-1-2, Class 1.3  
• ETSI EN 300 019-1-3 “Classification of environmental conditions; Stationary Use at Weath-  
er-Protected Locations,” Class 019-1-3, Class 3.3  
This equipment is designed to function without degradation during exposure to all test  
severities per Class 019-1-3 or 4, Class 3.3  
• ETS 300 753 “Acoustic Noise Emitted by Telecommunications Equipment: Declared noise  
emissions in accordance with ISO 9296 and ISO 7779:  
– The Operating and Idling Sound Power (LWAd) and the Operating and Idling sound  
pressure (LpAm) are not applicable for this equipment, since this equipment does not  
generate noise.  
2
61182301E1-5A  
 
   
Installation  
INSTALLATION  
C A U T I O N !  
SUBJECT TO ELECTROSTATIC DAMAGE  
OR DECREASE IN RELIABILITY.  
HANDLING PRECAUTIONS REQUIRED.  
CAUTION  
Electrostatic Discharge (ESD) can damage electronic modules.  
When handling modules, wear an antistatic discharge wrist strap  
to prevent damage to electronic components. Place modules in  
antistatic packing material when transporting or storing. When  
working on modules, always place them on an approved antistatic  
mat that is electrically grounded.  
After unpacking the NTU-8F, inspect it for damage. If damage has occurred, file a claim with  
the carrier then contact ADTRAN Customer Service. Refer to ”Appendix A, Warranty” for  
further information. If possible, keep the original shipping container for returning the NTU-8F  
for repair or for verification of shipping damage.  
Shipping Contents  
The contents include the following items:  
• NTU-8F  
Total Access 3000/3010 NTU-8 Single Fiber Quad E1 with Ethernet and Performance  
Monitoring Compliance Document (P/N 61182301E1-17)  
• Total Access 3000/3010 NTU-8 Single Fiber Quad E1 with Ethernet and Performance  
Monitoring Job Aid (P/N 61182301E1-22)  
Power Interface  
The power for the NTU-8F can be supplied through a –48 VDC supply connected to the  
backplane of the NTU-8F. The NTU-8F operates within a voltage range of –42 VDC to –56 VDC.  
Loop Connections  
The E1 loop connections are made through four RJ-45 type connectors. For each connector,  
transmit tip and ring are on pins 5 and 4, and receive tip and ring are on pins 2 and 1, respec-  
tively. Single-mode fiber is connected to the SC connector located on the back panel of the  
module.  
61182301E1-5A  
3
 
       
Total Access 3000/3010 NTU-8 Single Fiber Quad E1 Installation and Maintenance Practice  
Physical Installation  
To install the NTU-8F, perform the following steps:  
1. Place the unit in a location where a DC power source is available. This unit operates  
within a voltage range of –24 VDC to –48 VDC. If a wall-mount installation is required,  
attach the supplied hangers to the unit.  
2. Connect power to the NTU-8F housing. Power is connected to the NTU-8F by connecting  
the plus (+), minus (–), and ground wires to a three-position terminal block located at the  
right of the backplane (see Figure 2).  
Figure 2. NTU-8F Rear Panel  
When the NTU-8F first powers up, it runs power up self-tests. Once the power up self-test is  
complete, the status LEDs will reflect the true state of the hardware.  
Front Panel LEDs  
The NTU-8F provides front panel LEDs to display status information. The NTU-8F LEDs and  
status descriptions are shown in Table 2.  
Table 2. Front Panel LEDs  
Label  
PWR  
Status  
Description  
{
z
z
Off  
Power supply or fuse failure  
In Service  
Green  
Yellow  
Out of Service-Unassigned or Maintenance  
OPT  
{
z
z
Off  
Unit is Out of Service-Unassigned  
Green  
Red  
Unit is active and optical interface is synchronized  
Unit is active, but Rx loss on the optical interface  
PORT 1-4  
{
z
z
z
Off  
Port is provisioned Out of Service-Unassigned  
Port is provisioned and functioning properly  
Port is in loopback or a BERT is active  
Green  
Yellow  
Red  
Port is active with an active major alarm condition  
4
61182301E1-5A  
 
       
Installation  
Table 2. Front Panel LEDs (Continued)  
Label  
LBK  
Status  
Description  
{
z
z
z
Off  
No loopback on selected channel  
Green  
Yellow  
Red  
Selected G.703 E1 port in local loopback  
Selected G.703 E1 port in remote loopback (PN127 or V.54)  
Selected G.703 E1 port in local or remote loopback (PN127 or  
V.54); when no port is selected, this becomes an OR’d  
summation of all loopbacks on all ports  
BERT  
{
z
z
z
Off  
Selected G.703 E1 port BERT not active  
Green  
Yellow  
Red  
Selected G.703 E1 port BER, with no errors  
Selected G.703 E1 port BERT active with errors  
Selected G.703 E1 port active, but not in sync  
Rear Panel Connections  
Connectors on the rear panel (Table 3) provide for the following connections:  
Table 3. Rear Panel Connectors  
Connector  
Type  
Function  
Fiber Optic  
SC-type Optical  
Connect single-mode fiber (1310 nm transmit;  
1510 nm receive)  
Port 1-4  
ENET  
Craft  
RJ-45  
Connect four G.703 E1s  
Connect 10/100 Ethernet  
CAT 5 Modular Jack  
DB-8 (RS-232)  
used to view menus and upgrade the NTU-8F; No  
provisioning or testing can be initiated  
External Alarms  
–48V, 250 mA  
DB-15  
Connect to six external alarm inputs  
4-pin Terminal Block  
Connect to power (NTU-8F has a detachable  
mating terminal screw block)  
Figure 3 displays the NTU-8F Rear Panel connections.  
Figure 3. NTU-8F Rear Panel Connections  
61182301E1-5A  
5
 
     
Total Access 3000/3010 NTU-8 Single Fiber Quad E1 Installation and Maintenance Practice  
PROVISIONING  
The NTU-8F is automatically configured to match the LTU-8 settings and does not require local  
provisioning. Provisioning for the LTU-8 is via the Total Access 3000/3010 System Controller  
Unit (SCU). The SCU initiates and controls the transfer of commands and data to and from the  
LTU-8. The LTU-8 generates all menu items for both the LTU-8 and the NTU-8F. The LTU-8  
retains provisioning data in a nonvolatile memory device in the event of power loss.  
Viewing of all provisionable settings, status, and Performance Monitoring menus are supported  
from the NTU-8F local craft port, labeled CRAFT, but changes cannot be made. The craft port is  
a DB-9 connector that supplies an RS-232 interface for connection to a controlling terminal.  
The supported terminal type is VT100 or compatible and is set for the following:  
• 38400 bps  
• 8-data bits  
• no parity  
• no flow control  
• 1-stop bit  
Y-Modem flash upgrade is password protected from the NTU-8F. The default password is  
“password,” which can be changed from the NTU-8F.  
Provisioning Defaults  
On initial installation, the NTU-8F is set to factory default provisioning options. Table 4 list  
available options, with the default settings shown in bold type.  
Table 4. Provisioning Defaults  
NTU-8F  
Settings  
Defaults  
Card Service State  
In Service;  
Out of Service-Maintenance  
Out of Service-Maintenance;  
Out of Service Unassigned  
NTU Push Buttons  
External Alarms  
Disabled;  
Enabled  
Disabled  
Disabled;  
Enabled  
Disabled  
Change NTU Firmware  
Upgrade Password  
password  
password  
Port Service State  
In Service;  
Out of Service-Maintenance  
Out of Service-Maintenance;  
Out of Service-Unassigned  
E1 Frame Format  
FAS;  
FAS  
FAS+CRC4  
E1 Data Rate  
0h - FFh  
FFh  
FFh  
Timeslot Idle Pattern  
00h - FFh  
6
61182301E1-5A  
 
     
Provisioning  
Table 4. Provisioning Defaults (Continued)  
NTU-8F  
Settings  
Defaults  
LT Clock Source  
Internal Clock;  
G.703 Rx Clock;  
Fiber Rx Clock  
G.703 Rx Clock  
NT Clock Source  
Internal Clock;  
G.703 Rx Clock;  
Fiber Rx Clock  
Fiber Rx Clock  
Disabled  
ISDN-PRA V3  
Disabled;  
Enabled  
LTU Ethernet Service State  
In Service;  
Out of Service-Maintenance;  
Out of Service-Unassigned  
Out of Service-Maintenance  
Out of Service-Maintenance  
NTU Ethernet Service State  
In Service;  
Out of Service-Maintenance;  
Out of Service-Unassigned  
Ethernet Auto Negotiation  
Ethernet Duplex Mode  
Ethernet Speed  
Disabled;  
Enabled  
Enabled  
Half Duplex;  
Full Duplex  
Full Duplex  
100 Mbps  
10 Mbps;  
100 Mbps  
Fiber PM Thresholds  
E1 PM Threshold - ES  
Disabled  
Disabled  
Disabled  
Disabled  
61182301E1-5A  
7
 
Total Access 3000/3010 NTU-8 Single Fiber Quad E1 Installation and Maintenance Practice  
OPERATION  
The NTU-8F provides a platform to exchange data between four G.703 interfaces and an  
optical fiber interface. The customer data connection is via the RJ-45 connector on the unit.  
An optical fiber interface is provided for communication with the loop. The NTU-8F operates  
with an LTU-8 at the other end of the fiber optic cable.  
FRONT PANEL PUSHBUTTON  
Pushbuttons on the front panel (Table 5) provide the following functionality (when the option  
is enabled on the LTU-8).  
Table 5. Front panel Pushbuttons  
Pushbutton  
Port Select  
Function  
Press the PORT SELECT button to select the active port. Selection  
choices cycle through the provisioned G.703 E1 ports in following  
order:  
No Port, Port 1, Port 2, Port 3, and Port 4.  
Local Loop/ERR INJ  
Remote Loop  
With a port selected, and a Bit Error Rate Test (BERT) is not in  
progress, press the LOCAL LOOP/ERR INJ button to either initiate or  
terminate a local loop on the selected port.  
If a BERT is in progress, press the button to inject a single bit error.  
With a port selected, press the REMOTE LOOP button to place or  
remove a remote loop on the selected port's single data service. This  
action sends respective inband loop-up or loop-down patterns to  
the far end (in the associated data service timeslots).  
BERT  
With a port selected, and no local loops, press the BERT button to  
start or stop a BERT on the selected port.  
8
61182301E1-5A  
 
     
Specifications  
SPECIFICATIONS  
Specifications for the NTU-8F are detailed in Table 6.  
Table 6. NTU-8F Specifications  
Specification  
Description  
Environmental  
Operating Temperature: –5°C to +55°C  
Storage Temperature: –40°C to +85°C  
Relative Humidity: Up to 95% noncondensing  
Physical  
Dimensions: Height: 1.8 inches  
Width: 8.0 inches  
Depth: 9.0 inches  
Weight: 2.5 pound  
Power  
Input Voltage Range: –42 VDC to –56 VDC inputs  
Maximum Current Draw: 90 mA at –48 VDC  
Maximum Power Dissipation: 4.32 watts  
Optical  
Fiber Type: Single Mode  
Wave length: 1310 nm receive and 1550 nm transmit  
Optical Budget: 17 +1 dB  
Transmit Level: –14 +1 dB (worst case)  
Receive Level: –31 +1 dB (worst case)  
Connector: Single SC connector  
Connectors  
E1 Interface: RJ-45  
Fiber: Flat SC adapter  
Part Number  
NTU-8 Single Fiber Quad E1: 1182301E1  
Compliance  
Agency Approval: UL 60950  
61182301E1-5A  
9
 
   
Total Access 3000/3010 NTU-8 Single Fiber Quad E1 Installation and Maintenance Practice  
This page is intentionally blank.  
10  
61182301E1-5A  
 
Appendix A  
Warranty  
WARRANTY AND CUSTOMER SERVICE  
ADTRAN will replace or repair this product within the warranty period if it does not meet its  
published specifications or fails while in service. Warranty information can be found at  
Refer to the following subsections for sales, support, Customer and Product Service (CAPS)  
requests, or further information.  
ADTRAN Sales  
Pricing/Availability:  
800-827-0807  
ADTRAN Technical Support  
Pre-Sales Applications/Post-Sales Technical Assistance:  
800-726-8663  
Standard hours: Monday - Friday, 7 a.m. - 7 p.m. CST  
Emergency hours: 7 days/week, 24 hours/day  
ADTRAN Repair/CAPS  
Return for Repair/Upgrade:  
(256) 963-8722  
Repair and Return Address  
Contact CAPS prior to returning equipment to ADTRAN.  
ADTRAN, Inc.  
CAPS Department  
901 Explorer Boulevard  
Huntsville, Alabama 35806-2807  
61182301E1-5A  
A-1  
 
                 
®
Carrier Networks Division  
901 Explorer Blvd.  
Huntsville, AL 35806  
 

3Com Decking 09 1765 001 User Manual
ABC Office Paper Shredder 802CC User Manual
Abocom Network Card BTM100H User Manual
Accusplit Watch AE603EBL User Manual
Acoustic Research Headphones AW D510 User Manual
Activision Video Games 47875769977 User Manual
Aiphone Outdoor Cart KA 1MD User Manual
Allied Telesis Network Card AT 2500TX User Manual
Atlona Car Satellite TV System AT HDWP IR UK User Manual
Banner American Products Stud Sensor S18M User Manual