4
AlliedWare Plus™ Version 2.1.2
AT-9000 Layer 2-4 Gigabit Ethernet EcoSwitches
Software Release Notes
Please read this document before you begin to use the management software. The document
has the following sections:
Caution:
The software described in this document contains certain cryptographic functionality and its
export is restricted by U.S. law. As of this writing, it has been submitted for review as a “retail
encryption item” in accordance with the Export Administration Regulations, 15 C.F.R. Part 730-
772, promulgated by the U.S. Department of Commerce, and conditionally may be exported in
accordance with the pertinent terms of License Exception ENC (described in 15 C.F.R. Part
740.17). In no case may it be exported to Cuba, Iran, Iraq, Libya, North Korea, Sudan, or Syria. If
you wish to transfer this software outside the United States or Canada, please contact your local
Allied Telesis sales representative for current information on this product’s export status.
Supported Platforms
Version 2.1.2 of the AlliedWare Plus™ Management Software is supported on these switches:
AT-9000/28
AT-9000/28SP
AT-9000/52
This version supports the following SFP modules:
AT-SPTX (Supported only at a speed of 1G.)
PN 613-001447 Rev A
1
AlliedWare Plus Version 2.1.2 Software Release Notes
Upgrading the AT-9000 Switch to AlliedWare Plus Version 2.1.2 from Version 2.1.1
This section contains the procedure for upgrading the switch from AlliedWare Plus Version 2.1.1
to version 2.1.2, from the command line. Here are the upgrade requirements:
There must be a TFTP server on your network.
The switch must be assigned an IP address. For instructions, refer to the AT-9000 AlliedWare
Plus User’s Guide.
Caution:
The upgrade process is disruptive to network operations because it resets the switch. The switch
does not forward network traffic during the reset.
There are three phases to upgrading the switch:
Phase 1. Uploading the Active Boot Configuration File to Your TFTP Server
Allied Telesis recommends uploading the active boot configuration file from the switch to your
TFTP server before updating the management software on the switch. You’ll use the file in phase
3 to check for v2.1.1 commands that are not compatible with v2.1.2. To upload the active boot
configuration file:
1. Start the TFTP server on your network.
1. Start a local or remote management session on the switch.
2. When prompted, enter a username and password. The defaults are “manager” for the
username and “friend” for the password.
3. Move to the Privileged Exec mode and enter the SHOW BOOT command to display the
name of the active boot configuration file:
awplus# show boot
Here is an example of the information.
Current software : v2.1.1
Current boot image : v2.1.1
Backup boot image : Not set
Default boot config: /cfg/boot.cfg
Current boot config: /cfg/sw2bldg2.cfg (file exists)
The name of the active boot configuration file is displayed in the “Current boot config” line.
4. Use the COPY command to upload the boot configuration file from the switch to the TFTP
server. Here is the format of the command:
copy flash tftp ipaddress filename.cfg
The IPADDRESS parameter is the IP address of the TFTP server. The FILENAME
parameter is the name of the boot configuration file you want to upload from the switch to
TFTP server. The filename extension must be “.cfg” for boot configuration files. The filename
cannot contain spaces.
PN 613-001447 Rev A
3
Allied Telesis, Inc.
AlliedWare Plus Version 2.1.2 Software Release Notes
This example of the command uploads the boot configuration file “sw2bldg2.cfg to a TFTP
server that has the IP address 149.182.34.15:
awplus# copy flash tftp 149.182.34.15 sw2bldg2.cfg
5. Go to Phase 2.
Phase 2: Downloading the New AlliedWare Plus Version 2.1.2 Management Software
To upgrade the switch to AlliedWare Plus Version 2.1.2 from AlliedWare Plus Version 2.1.1:
1. Store the AlliedWare Plus Version 2.1.2 Management Software on the TFTP server on your
network.
2. If you have not already started the TFTP server, start it now.
3. If you have not already started a local or remote management session on the switch, start a
session now.
4. Use the ENABLE command to move to the Privileged Executive mode.
awplus> enable
awplus#
5. Use the COPY command to download the AlliedWare Plus Version 2.1.2 Management
Software from the TFTP server to the switch. Here is the format of the command:
copy tftp flash ipaddress filename
The IPADDRESS parameter specifies the IP address of the TFTP server on your network.
The FILENAME parameter specifies the filename of the AlliedWare Plus Version 2.1.2
Management Software stored on the TFTP server. The extension must include the “.img”
extension. The name cannot contain spaces or special characters.
In this example, the IP address of the TFTP server is 149.157.18.78 and the name of the
management software file is “ats-9000-2.1.2.img:”
awplus# copy tftp flash 149.157.18.78 ats-9000-2.1.2.img
After receiving the file from the TFTP server, the switch writes it to flash memory and resets.
The entire process takes several minutes. The switch is running the new software after it
completes the reset.
6. Establish a new management session with the switch.
7. Enter the Privileged Exec mode and enter the WRITE command to same the configuration.
awplus> enable
awplus# write
8. Go to Phase 3.
Phase 3: Updating the Commands
A few commands have changed from v2.1.1 to v2.1.2. If the switch encountered any of these
commands in its boot configuration file when it reset, it skipped over them to remove them from
its running configuration. To complete the upgrade procedure, you should print out the boot
configuration file you uploaded to your TFTP server in Phase 1, and examine it for any of the
modified commands. The modified commands are described here:
BANNER EXEC and BANNER MOTD Commands - The formats of these commands, which
are used to create the User Exec and Privileged Exec modes banner and message-of-the-
day banner, have changed in v2.1.2. Where before a command and its banner message were
included on the same line, they are now entered separately. The new formats are:
banner exec
banner motd
PN 613-001447 Rev A
4
Allied Telesis, Inc.
AlliedWare Plus Version 2.1.2 Software Release Notes
After you enter a banner command, the prompt “Type CTRL/D to finish” is displayed on your
screen, at which point you may enter a banner message of up to 50 characters for the User
Exec and Privilege Exec modes banner and 100 characters for the message-of-the-day
banner. Spaces and special characters are allowed. When you are finished entering a
message, hold down the CTRL key and type D to return to the command prompt in the Global
Configuration mode. To test the banner for the User Exec and Privilege Exec modes, return
to the Privileged Exec mode and issue the CLEAR SCREEN command. To test the
message-of-the-day banner, log out and log in again.
This example creates the User Exec and Privilege Exec modes banner “Engineering Switch
Building 12:”
awplus> enable
awplus# configure terminal
awplus(config)# banner exec
Type CNTL/D to finish
Engineering Switch Building 12
awplus(config)#
This example creates the message-of-the-day banner “Updated November 12, 2010:”
awplus> enable
awplus# configure terminal
awplus(config)# banner motd
Type CNTL/D to finish
Updated November 12, 2010
awplus(config)#
LOG BUFFERED Command - The function and format of the LOG BUFFERED command
has not changed, but the FAN_CTRL option is no longer supported. If the command and
option are in the backup boot configuration file, reenter the command on the switch, omitting
the option.
FILTERING Command - This command, which In v2.1.1 allowed you to block ingress
broadcast, multicast, or unknown unicast packets on ports, is not supported in version 2.1.2.
There is no equivalent v2.1.2 command.
CLOCK TIMEZONE Command - If the switch is using an SNTP or NTP server as the source
of its date and time, you have to reenter the CLOCK TIMEZONE command because its
format has changed. You may now specify both hours and minutes to identify the difference
between local time and UTC, whereas before the command only accepted hours. The new
format of the command is:
clock timezone +hh:mm|-hh:mm
HH are hours in the range of -12 to +12 and MM are minutes in the range of 00 to 60. The
offset must include a plus or minus sign. You must include both the hours and minutes, and
both values must have two digits. The example sets the UTC offset to +2 hours:
awplus> enable
awplus# configure terminal
awplus(config)# clock timezone +02:00
The example sets the UTC offset to -8 hours, 15 minutes:
awplus> enable
awplus# configure terminal
awplus(config)# clock timezone -08:15
PN 613-001447 Rev A
5
Allied Telesis, Inc.
AlliedWare Plus Version 2.1.2 Software Release Notes
SET SFLOW COLLECTOR IP Command - In v2.1.1 this command in the Port Interface mode
was used to identify the sFlow collector that was to be the recipient of packet data from a
port. This command is not supported in v2.1.2 because you may specify only one sFlow
collector for the switch. The collector is identified with the SFLOW COLLECTOR IP command
in the Global Configuration mode.
IP ACCESS-GROUP command - The function of this command, which is used to assign
access control lists (ACLs) to ports, has not changed in v2.1.2, but the IP keyword has been
removed, shortening the command to just ACCESS-GROUP. To reapply the ACLs to the
ports, it will be necessary to reenter the command in the Port Interface modes of the
appropriate ports. To do this, examine the backup configuration file for any IP ACCESS-
GROUP commands and then reenter the same commands, but without the IP keyword, in the
Port Interface modes of the affected ports.
Troubleshooting the Upgrade Procedure
If you have a problem downloading the management software to the switch from your TFTP
server, here are a few suggestion on how to resolve it:
Check that the TFTP server on your network is active.
Use the SHOW IP INTERFACE command in the User Exec or Privileged Exec mode to verify
that the switch has an IP address.
Use the PING command in the Privileged Exec mode to check for an active link between the
switch and your TFTP server.
Verify that you entered the COPY command correctly. Be sure to include the “.img” extension
in the filenames of the management software file.
If you are using a TFTP server that is case sensitive, be sure to use upper and lowercase
characters when specifying filenames in the commands.
Check that the management software file is stored in the correct directory on the TFTP
server.
Operational Notes
The speed of the AT-SPFX/2 and AT-SPFX/15 modules has to be manually set to 100Mbps
with the SPEED command. This example of the command configures the speed of the AT-
SPFX/2 or AT-SPFX/15 module in slot 1 of an AT-9000/28SP Switch:
awplus> enable
awplus# configure terminal
awplus(config)# interface port1.0.1
awplus(config-if)# speed 100
The assignment of an IPv6 management address to the switch must be performed manually
using the IPV6 IPADDRESS command, because the switch cannot obtain an IPv6 address
with stateless autoconfiguration or from a DHCP6 server.
You cannot use the web browser interface to configure these features:
— Access control lists
— Enhanced stacking
— Quality of Service
— SNMP
— Voice VLANs
PN 613-001447 Rev A
6
Allied Telesis, Inc.
AlliedWare Plus Version 2.1.2 Software Release Notes
— VLAN stacking
Use the command line interface to configure these features.
The web browser interface has been tested and found to be compatible with the following
web browsers:
— Microsoft Internet Explorer 7 and 8
— Mozilla Firefox 3.6.3
— Apple Safari 4.0.5
Note:
If you are using Explorer 8 web browser and the pull-down menus in the switch’s web browser
interface do not work, open the Internet Options window in the web browser, select the Security
tab, and set the custom settings to medium-high. Then refresh your page.
You cannot change the configuration of a port, such as its VLAN assignment, after it is added
to a static or an LACP trunk. The configuration of a port must be set before it is added to a
trunk.
You can create up to 4096 VLANs on the switch, but only 255 VLANs can be active at a time.
Changing the SNMPv3 engineID value is not recommended because the SNMP server on
the switch may fail to operate properly.
Resolved Issues
The following issues were resolved in this release.
SNMP server: The SNMP server stopped working during SNMP walks. (8222)
SNMP server: The SNMP server stopped working if you activated the HTTP or HTTPS server
and reset the switch. (8148)
SNMP and Telnet servers: A memory leak problem in the SNMP and Telnet servers caused
the switch to reset after forty management sessions. (8318)
SNMP server: Access control lists created with SNMP were deleted by the switch. (8651)
SNMP server: The switch displayed debug messages during local management sessions if
there was also an active SNMP session. (8646)
SNMP server: The switch periodically displayed an IPC_TIMEOUT_ERROR message when
it was managed with SNMP. (8201)
SNMP traps: The switch sent SNMP traps even when they were disabled. (8650)
Port configuration: The SHOW INTERFACE command displayed negative numbers. (8263)
SNTP client: The CLOCK TIMEZONE command did not accept minutes in its format. (8145)
SNTP client: The SHOW NTP ASSOCIATIONS command did not display the UTC offset
correctly. (8196)
SNTP client: System time drifted forward if it was set by an NTP or SNTP server. (8612)
SNTP client: The NTP client did not synchronize properly with the Microsoft Windows XP
Time server. (8626)
SNTP client: The client periodically caused the switch to stop forwarding network traffic.
(8637)
PN 613-001447 Rev A
7
Allied Telesis, Inc.
AlliedWare Plus Version 2.1.2 Software Release Notes
Port-based and tagged VLANs: You could not change a port from the trunk mode to the
access mode. (8319)
IGMP snooping: The switch did not properly register IGMP queries and reports. (8301)
sFlow client: The switch stopped forwarding traffic if the sFlow client was active on more than
twelve ports. (8236)
STP and enhanced stacking: The switch stopped forwarding traffic if both STP and enhanced
stacking were activated. (8246)
STP: The switch would reset if the spanning tree protocol detected a loop in the network
topology. (8094)
STP: The spanning tree protocol stopped sending BPDUs when the SNTP client
synchronized system time with an NTP or SNTP server. (8605)
STP: The spanning tree SHOW commands did not display the settings for BPDU guard, root
guard, portfast and other parameters. (8639)
RADIUS client: The RADIUS acronym was misspelled in the web browser interface. (8625)
GVRP: Dynamic GVRP VLANs were saved as static VLANs in the active boot configuration
file. They are now relearned when the unit is reset. (8321)
ACLs: The copy-to-mirror option did not work. (8675)
LACP: The switch disabled the remaining ports of an eight port LACP trunk if the connections
were lost on four of the ports. (8599)
LACP: LACP trunks caused the switch to display a “Kernel paging request” error message
and to reset. (8618)
LACP: The switch would reset if a port in an LACP trunk that had 20 or more ports lost its
connection.(8638)
LACP: There was a delay in the resumption of traffic on LACP connections that changed link
states. (8619)
LACP: Fluctuating connections in LACP trunks resulted in IPC errors. (8622)
Telnet server: You could not overwrite existing encryption keys from a Telnet management
session. (8616)
SSH server: You could start a remote SSH management session without having to enter a
username. (8712)
SSH server: The switch did not properly timeout inactive remote SSH management sessions.
Known Issues
There are no known issues in this release.
PN 613-001447 Rev A
8
Allied Telesis, Inc.
AlliedWare Plus Version 2.1.2 Software Release Notes
Changes to the AlliedWare Plus Command Line User’s Guide
Here are the main changes to the AlliedWare Plus Command Line User’s Guide for version
2.1.2.
Table 1. Changes to the AlliedWare Plus Management Software User’s Guide for Version 2.1.2
Chapter
Description
Chapters 5 and 6: Basic
Switch Management
The formats of the BANNER EXEC and BANNER MOTD
commands in the Global Configuration mode have changed
such that the banner messages are now entered separately from
the command.
The HOSTNAME command now accepts special characters, but
not spaces or quotation marks.
The command reference chapter now includes the SYSTEM
TERRITORY command, for designating the territory where the
switch is installed.
Chapters 7 and 8: Port
Parameters
Revision A of the user’s guide incorrectly stated that you had to
disable Auto-Negotiation to manually set the speed, duplex
mode and MDI/MDI-X settings on the ports. Revision B states
that all three settings may be set independently of each other.
For example, you could configure a port such that its speed is
set manually to 100 Mbps, its duplex mode to Auto-Negotiation,
and its wiring configuration to MDI.
The FILTERING and NO FILTERING commands described in
Revision A of the guide are no longer supported on the switch.
Chapters 11 and 12:
Simple Network Time
Protocol Client
The format of the CLOCK TIMEZONE command has been
modified to accept minutes in the UTC offset, which the switch
uses to convert UTC time into local time.
Chapter 20: Multicast
Commands
New commands for blocking unknown multicast packets.
Chapters 26 and 27: File
Transfers
You may no longer use Zmodem to download new management
software to the switch. That management task must be
performed with TFTP. You may use Zmodem to upload or
download boot configuration files, encryption key certificates or
requests, and diagnostic text files.
Chapter 29: Event Log
Commands
The SHOW LOG command no longer supports the FAN_CTRL
module.
Chapters:50 and 51: VLAN VLAN stacking is a new feature.
Stacking
PN 613-001447 Rev A
9
Allied Telesis, Inc.
AlliedWare Plus Version 2.1.2 Software Release Notes
Table 1. Changes to the AlliedWare Plus Management Software User’s Guide for Version 2.1.2
Chapter
Description
Chapter 52: MAC Address- Revision A of the user’s guide stated in Guidelines that this type
based Port Security
of port security was not supported on optional GBIC, SFP, or
XFP modules. Revision B states that MAC address-based port
security is supported on SFP transceivers, the only type of
transceivers AT-9000 switches support.
Chapters 59 and 60: sFlow Revision A of the user’s guide stated you could define the IP
Agent
addresses of up to four sFlow collectors. The switch actually
supports the IP address of just one collector. This is corrected in
Revision B.
Chapters 67 and 68:
Access Control Lists
(ACLs)
Revision A stated that a port that had more than one ACL
performs them according to their ID numbers, in ascending
order. ACLs are actually performed in the order in which they are
applied to a port. This is corrected in Revision B.
The IP ACCESS-GROUP command, which is used to assign
ACLs to ports, has been shortened to ACCESS-GROUP
command.
The previous version of the user’s guide stated that ACLs
without the VLAN parameter applied to both tagged and
untagged packets. That is incorrect. ACLs without the VLAN
parameter apply only to untagged packets.
Chapters 70 and 71: Local This version of the management software has a NO SERVICE
Manager Accounts
PASSWORD-ENCRYPTION command that disables password
encryption of local manager accounts. In the previous version,
you could not disable password encryption after you had
activated it.
Previously, manager accounts with a privilege level of 1 could
access all of the command modes except when command mode
restriction was activated, in which case they were restricted to
the User Exec mode, unless they knew the special password. In
this release, command mode restriction is always activated to
prevent managers who have a privilege level of 1 and do not
know the special password from accessing any mode beyond
the User Exec mode.
Chapter 74 and 75: Telnet In the previous release the Telnet client could only be used from
Client
local management sessions of the switch. In this release you
may use it from local and Telnet management sessions.
PN 613-001447 Rev A
10
Allied Telesis, Inc.
AlliedWare Plus Version 2.1.2 Software Release Notes
Table 1. Changes to the AlliedWare Plus Management Software User’s Guide for Version 2.1.2
Chapter
Description
Chapter 77: SSH Server
Commands
The following commands documented in revision A are not in
the firmware and have been removed from revision B:
SSH SERVER LOGIN-TIMEOUT Command
SSH SERVER MAX-STARTUPS Command
SSH SERVER SESSION-TIMEOUT command
Administrators may use the EXEC-TIMEOUT command in place
of the SSH SERVER SESSION-TIMEOUT command to set the
session timeout timers.
PN 613-001447 Rev A
11
Allied Telesis, Inc.
AlliedWare Plus Version 2.1.2 Software Release Notes
Contacting Allied Telesis
This section provides Allied Telesis contact information for technical support as well as sales or
corporate information.
Online Support
You can request technical support online by accessing the Allied Telesis Knowledge Base:
www.alliedtelesis.com/support/kb.aspx. You can use the Knowledge Base to submit
questions to our technical support staff and review answers to previously asked questions.
Email and Telephone Support
For Technical Support via email or telephone, refer to the Support & Services section of the
the website. then select the appropriate menu tab.
Warranty
For hardware warranty information, refer to the Allied Telesis web site: www.alliedtelesis.com/
support/warranty.
Returning Products
Products for return or repair must first be assigned a return materials authorization (RMA)
number. A product sent to Allied Telesis without an RMA number will be returned to the sender at
the sender’s expense. For instructions on how to obtain an RMA number, go to our web site at
www.alliedtelesis.com and then select Support and Replacement Services.
Sales or Corporate Information
You can contact Allied Telesis for sales or corporate information through our web site:
Management Software Updates
New releases of management software for our managed products are available on our Allied
Copyright © 2010 Allied Telesis, Inc.
All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesis,
Inc.
Allied Telesis and AlliedWare Plus are trademarks of Allied Telesis, Inc. All other product names, company names,
logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners.
Allied Telesis, Inc. reserves the right to make changes in specifications and other information contained in this
document without prior written notice. The information provided herein is subject to change without notice.
PN 613-001447 Rev A
12
Allied Telesis, Inc.
|