Troubleshooting Guide
Problem
Reason
Solution
Unit does not turn on.
1. Power Cord
1. Check to make sure
power cord is plugged
in.
2. Switch
2. Check to make sure
switch is in the on posi-
tion.
3. AHPCO™ Cell
3. Check to make
sure UV lamp within
AHPCO™
Cell
in
plugged in completely.
Induct 9
Owner’s
Manual
Unit is not reducing
odors.
1. Defective AHPCO™
Cell
1. Check to make sure
the AHPCO™ Cell has
a blue glow. If you see
no glow or the glow has
turned to a purple color,
contact Air Oasis.
This Manual Includes:
• Warranty
• Safety Warnings
• Installation Instructions
• Operating Instructions
• Replacement Directions
• Troubleshooting Tips
irway Blvd
Amarillo, TX 79118
Before operating this unit or replacing the AHPCO™
Cell carefully read the contents of this manual.
Toll-Free: 1-800-936-1764 Fax: 1-806-373-7799
Copyright© 2006 Air Oasis All Rights Reserved
Induct 9 Installation Instructions
Step 1
Tear out the
cutout template and
trace the circle onto
the ductwork and cut
hole .
Step 2
Remove the
wax paper from the
gasket.
If you do not have a hole saw tear this page off and cut the
circle out. Then place on the ductwork in desired position
and trace the rectangle. Drill holes as indicated and then
use a jig saw or metal cutting snips to cut out the circle.
Step 3
Insert unit into
pre-cut hole.
Cut Out
Step 4
Drill the metal
tapping screws in to
hold unit in place.
Read all instructions carefully before operating
your air purifier.
Step 4
Plug the power cord into an electrical outlet. You may optionally have an
electrician wire the air purifier to your HVAC unit so that the air purifier only
operates when your HVAC fan is running. Once the unit is plugged in the
indicator light should glow to indicate the AHPCO Cell is working properly.
Table of Contents
Safety Instructions and Cautions
Table of Contents
1
2
3
Warranty
Maintenance and Customer Service
Placement and Operation
Cleaning
4
4
AHPCO™ Cell Replacement
Step 1
4
CAUTION: Before attempting to service the Air Oasis unit, be sure the
power is off and unplugged.
AHPCO™ Cell Replacement
Troubleshooting Guide
5-6
7
Remove three (3) screws at the top of
the aluminum face plate. Then slide
the face plate up and off.
Step 2
Unplug the four pin lamp connec-
tors and fiber optic cords from the
AHPCO Cell.
5
2
Warranty
Maintenance and Customer Service
If you require any additional information or have problems with your Air Oasis ap-
pliance, you may call Air Oasis customer service at:
1-800-936-1764
Air Oasis gives you the following limited warranty for this product only if it was origi-
nally purchased for residential or commercial use but, not resale from Air Oasis or
an Air Oasis Authorized Retail Dealer.
Please have your serial and model numbers, found on bottom of the unit, handy
when calling.
Air Oasis will repair or replace, free of charge, to the original purchaser, any part
that is found to be defective in material or workmanship within three (3) years of
the date of purchase.
Save your sales receipt to show if your Air Oasis appliance should ever need any
warranty service.
This limited warranty covers the replacement of a defective AHPCO Cell for a pe-
riod of three years.
Installation and Operation
This limited warranty does not apply to any part subjected to accident, abuse, cer-
tain commercial uses, alteration, misuse, damage caused by act of God, the use
of voltages other than indicated on the label displayed on this product or service of
this product by anyone other than Air Oasis.
It’s strongly recommended that only a licensed electrician
or HVAC installer properly install this unit.
The purifiers can be installed on either the return or supply side of the
plenum.
Air Oasis does not authorize any person or representative to assume or grant any
other warranty obligation with the sale of this product.
Step 1
Air Oasis’ limited warranty is valid only if you retain proof of purchase from Air Oa-
sis or an Air Oasis Authorized Retail Dealer for this product. If you purchase this
product from any other source, your purchase is “AS IS”, which means Air Oasis
grants you no warranty, and that you, not Air Oasis, assume the entire risk of the
quality and performance of this product, including the entire cost of any necessary
servicing or repairs of any defects.
Cut a 2” hole in the plenum using a hole
saw. Make sure the hole is centered so
that no part of the mounting plate is hang-
ing off the edges of the plenum when the
probe is inserted.
Air Oasis’ liability for damages to you for any costs whatsoever arising out of this
statement of limited warranty shall be limited to the amount paid for this product
at the time of original purchase, and Air Oasis shall not be liable for any direct,
indirect, consequential or incidental damages arising out of the use or inability to
use this product.
Step 2
Insert the probe into the 2” hole until the
back mounting plate is flush against the
plenum surface. We recommend mounting
the unit with the rectangular side facing ei-
ther left or right, but not down or up.
ALL EXPRESS AND IMPLIED WARRANTIES FOR THIS PRODUCT, INCLUDING
IMPLIED WARRANTIES OF MERCHANTABILITYAND FITNESS FOR A PARTIC-
ULAR PURPOSE, ARE LIMITED IN DURATION TO THE WARRANTY PERIOD,
AND NO WARRANTIES, WHETHER EXPRESS OR IMPLIED, WILL APPLY AF-
TER THIS PERIOD.
Step 3
Some states do not allow limitations on the duration of implied warranties, so the
above limitation may not apply to you. This warranty gives you specific legal rights,
and you may also have other rights which vary from state to state.
Attach the mounting plate to the plenum
surface using sheet metal screws. There
are predrilled holes on the mounting plate
that can be used as a guide. It’s recom-
mended to seal the edges of the mounting
plate using aluminum insulation tape.
To obtain warranty service and return authorization number, contact us at:
PH: (800) 936-1764, FAX: (806) 373-7799 or E-mail to [email protected]
NOTE: All returned packages that do not have an RMA# will be refused.
3
4
|