Agilent Technologies Network Router Agilent E1345A User Manual

Agilent E1345A  
16-Channel Low-Offset Relay  
Multiplexer  
Data Sheet  
1-Slot, B-size, register based  
General purpose, low-offset relay multiplexer  
Low thermal offset reed relays, <4 µV  
16-channel 3-wire or 8-channel 4-wire multiplexer  
Shunt/series signal conditioning elements  
Channel scanning with Agilent DMMs  
Agilent E1345A  
Refer to the Agilent Technologies Website for instrument  
driver availability and downloading instructions, as well as for  
recent product updates, if applicable.  
Description  
The Agilent E1345A General-Purpose Reed Relay Multiplexer  
is a B-size, 1-slot, register-based VXI module that  
switches 16 channels of high, low, and guard each. The  
multiplexer has low thermal offset performance. This module  
consists of a B-size component card (labeled E1345-66201)  
and a screw terminal block that plugs onto the component  
card. The E1345A is functionally similar to the E1347A.  
Configuration  
One analog bus cable is shipped with each module, making it  
easy to connect common outputs together for slot-adjacent  
modules. If you are using a B-size mainframe, Agilent E1300B  
or E1301B, use the analog bus cable shipped with the E1326B  
DMM to connect it to the multiplexer(s).  
The E1345A multiplexer is arranged into two banks of eight  
switches, each having its own common high, low, and guard  
screw terminals accessible on the terminal block. Tree-  
switched common high, low, and guard screw terminals and  
analog bus connections provide access to all 16 channels. The  
module may be programmed as either a single 1x16 three-wire  
multiplexer, two independent 1x8 three-wire multiplexers (for  
four-wire ), or a 1x8 six-wire multiplexer.  
C-size Adapter  
For installing the E1345A in a C-size mainframe, the E1403C  
active adapter is recommended.  
PDFINFO H 5  
6
0
1
-
0
1
 
Module Current  
IPM  
IDM  
+5 V:  
+12 V:  
–12 V:  
+24 V:  
–24 V:  
–5.2 V  
–2 V:  
0.2  
0.13  
0
0.01  
0.01  
0
0
0
0
0
0
0
0
0
Cooling/Slot  
Watts/slot:  
P mm H2O:  
Air Flow liter/s:  
Analog bus cables for MUX-to-MUX and MUX-to-multimeter  
connections  
1.00  
0.02  
0.10  
Ordering Information  
Description  
Product No.  
16-Channel Low-Offset Relay Multiplexer  
Service Manual  
Japan - Japanese Localization  
3 Yr. Retn. to Agilent to 1 Yr. OnSite Warr.  
Extra terminal block for the E1345A  
E1345A  
E1345A 0B3  
E1345A ABJ  
E1345A W01  
E1345-80001  
Analog bus cables for MUX-to-MUX and MUX-to-multimeter  
connections  
3
PDFINFO H 5  
6
0
1
-
0
3
 
Signal Conditioning Components/Current Shunt  
4
PDFINFO H 5  
6
0
1
-
0
4
 
Related Literature  
2000 Test System and VXI Catalog CD-ROM,  
Agilent Pub. No. 5980-0308E (detailed specifications for VXI products)  
Agilent Technologies’ test and measurement service/support  
commitment  
Agilent strives to maximize the value our test and measurement products give  
you, while minimizing your risk and service/support problems. We work to  
ensure that each product is realistically described in the literature, meets its  
stated performance and functionality, has a clearly stated global warranty, and  
is supported at least five years beyond its production life. Our extensive self-  
help tools include many online resources (www.agilent.com).  
2000 Test System and VXI Catalog,  
Agilent Pub. No. 5980-0307E (overview of VXI products )  
1998 Test System and VXI Products Data Book,  
Agilent Pub. No. 5966-2812E  
Experienced Agilent test engineers throughout the world offer practical  
recommendations for product evaluation and selection. After you purchase an  
Agilent product, they can provide no-charge assistance with operation  
verification and basic measurement setups for advertised capabilities. To  
enhance the features, performance, and flexibility of your test and measurement  
products—and to help you solve application challenges—Agilent offers free or  
extra-cost product options and upgrades, and sell expert engineering,  
calibration, and other consulting services.  
Online  
Internet access for Agilent product information, services and support  
VXI product information  
Phone and fax  
United States:  
Defense Electronics Applications  
www.agilent.com/find/defense_ATE  
Agilent Technologies  
(tel) 1 800 452 4844  
Agilent Technologies VXI Channel Partners  
Canada:  
Agilent Technologies Canada Inc.  
(tel) 1 877 894 4414  
Agilent Technologies’ HP VEE Application Website  
Europe:  
Agilent Technologies  
Test & Measurement  
European Marketing Organisation  
(tel) (31 20) 547 2000  
Agilent Technologies Data Acquisition and Control Website  
Agilent Technologies Instrument Driver Downloads  
Japan:  
Agilent Technologies Japan Ltd.  
(tel) (81) 426 56 7832  
(fax) (81) 426 56 7840  
Agilent Technologies Electronics Manufacturing Test Solutions  
Latin America:  
Agilent Technologies  
Latin American Region Headquarters, U.S.A.  
(tel) (305) 267 4245  
(fax) (305) 267 4286  
Get assistance with all your test and measurement needs at  
or check your local phone book for the Agilent office  
near you.  
Australia/New Zealand:  
Agilent Technologies Australia Pty Ltd.  
(tel) 1 800 629 485 (Australia)  
(fax) (61 3) 9272 0749  
(tel) 0 800 738 378 (New Zealand)  
(fax) (64 4) 802 6881  
Asia Pacific:  
Agilent Technologies, Hong Kong  
(tel) (852) 3197-7777  
(fax) (852) 2506-9284  
Data Subject to Change  
©Agilent Technologies 2000  
Printed in the U.S.A. 04/2000  
Publication No.: 5965-5601E  
 

ADC Power Supply ACE COM L1 User Manual
ADC Switch Radiator II User Manual
ADTRAN Power Supply Power Supply Battery Charger User Manual
Agilent Technologies Network Router 8714 User Manual
Aiwa CRT Television TV S2700 User Manual
Alpine Car Stereo System VPA B222 User Manual
Altec Lansing Speaker System iMT525 User Manual
AMD Microscope Magnifier Am186TMER User Manual
American Audio Stereo Amplifier VLP1500 User Manual
Asus Network Card LS99 User Manual