ACR Electronics Security Camera 19303 User Manual

PRODUCT SUPPORT MANUAL  
RCL-100D //  
Remote Control Searchlight System  
Model No.: RCL-100D  
Product No.: 1930.3, 1931.3  
Y1-03-0138 Rev. V  
ACR Electronics, Inc., // 5757 Ravenswood Road // Fort Lauderdale // FL // 33312-6645  
 
RCL-100D, 12/24V  
REMOTE CONTROL SEARCHLIGHT SYSTEM  
SEARCHLIGHT  
Figure 1 - Remote Control Searchlight System  
SECTION 1 - FOREWORD  
Congratulations and thank you for purchasing the ACR RCL-100D  
Searchlight. The combination of computer aided design, high quality  
raw materials, and quality-controlled manufacturing produce a  
superior product. The Test Facility at ACR can reproduce some of the  
harshest environmental conditions known to man. This assures that  
the products we produce can stand up to the tough marine  
environment. With proper care and maintenance your searchlight will  
be in service for years to come.  
ACR is proud to be ISO 9001 certified, the International Standard for  
Quality.  
Y1-03-0138V  
3
 
 
SECTION 2 - GENERAL  
The RCL-100D was specially designed for mariners who require a  
high intensity remote controlled searchlight that can stand up to the  
tough marine environment.  
The RCL-100D Searchlight System contains a narrow beam  
searchlight that produces 200,000 peak candle power by combining  
two 55W halogen lamps with our unique optical quality parabolic  
reflectors.  
All functions of the Searchlight can be electrically operated by remote  
control from the pilot area of the vessel using the URP-102 Point  
Pad™, URC-102 Master Controller, and interconnect cable supplied  
with the RCL-100D. Searchlights equipped with the URC-102 Master  
Controller now have ACR's unique XRCiZfeature. The XRCiZ™  
feature routinely operates all moving parts in the Searchlight to keep  
the motors and drive mechanism freely running.  
SECTION 3 - SEARCHLIGHT  
The sleek design and modern construction of the Searchlight body  
makes it attractive for recreational and commercial vessels. The  
Searchlight is totally enclosed and is made of rugged aluminum alloy.  
It is gasketed and finished to be resistant to the weather.  
Mounting  
Make sure the area is clean and dry. The Searchlight can be mounted  
where desired, using appropriate length 3/16" diameter, stainless  
steel fasteners. Four (4) nylon shoulder washers are supplied with the  
RCL-100D Searchlight. The nylon washers prevent a galvanic  
reaction between the mounting hardware and the base of the  
Searchlight. Be sure these washers have been inserted in the base  
mounting holes and that the mounting base gasket is securely in  
place before bolting down. Silicone grease should be applied to the  
bottom of the gasket to help in waterproofing the unit. When  
mounting, be sure that the Searchlight is able to rotate 360° without  
hitting any obstructions. For the drilling hole pattern, refer to the  
Searchlight Mounting Template, supplied in the Mounting Templates.  
CAUTION: Do not mount the searchlight upside down. Moisture  
will not be able to drain from the inverted light head assembly.  
Y1-03-0138V  
4
 
   
NOTE: The Searchlight should be left uncovered if the XRCiZ feature  
is enabled.  
SECTION 4 - REMOTE CONTROL SYSTEM  
The Remote Control System consists of the URC-102 Master  
Controller and the URP-102 Point Pad™. This system is compatible  
with 12 VDC and 24 VDC systems without modification. The Remote  
Control System may be used with 12 V or 24 V Searchlights, ONLY  
THE LAMPS IN THE LIGHT HEAD ASSEMBLY MUST BE  
CHANGED TO MATCH THE VOLTAGE RATING.  
SECTION 5 - URP-102 POINT PAD™  
Case Options  
The URP-102 Point Pad™ is supplied as a surface mount unit (see  
Figure 4). A flush mount option is provided (see Figure 5). To switch  
mounting options, unscrew the six (6) screws on the unit’s back plate  
and remove the front cover. Fit the Point Pad™ with the flush mount  
cover, replace the back plate, and screw the unit back together.  
Mounting  
Both the surface mount and flush mount options require access to the  
backside of the mounting location. Make sure there are no  
obstructions behind the area where the switch is to be located (e.g.  
bulkheads, wires, plumbing, or hardware). Check in advance that the  
coax cable from the Master Controller can be routed to this location.  
Generally, the Point Pad™ should be mounted in a protected area.  
Install the surface mount Point Pad™ by drilling 3 holes in the  
dashboard location using the Point Pad™ Surface Mount Template  
supplied in the Mounting Templates. Mount the Point Pad™ to the  
dashboard using the gasket, washers, and nuts supplied. Use a  
sealant around the bolt holes to protect from moisture intrusion.  
When the flush mount option is selected, cut a rectangular hole in the  
dashboard location using the Point Pad™ Flush Mount Template  
supplied in the Mounting Templates. Use the gasket, washers, nuts,  
and the two U-Clamps provided to secure the Point Pad™. Use a  
sealant around the cut out to protect from moisture intrusion.  
Connecting to the Master Controller  
The Point Pad™ communicates with the Master Controller via  
standard television type RG-59 coaxial cable. The connectors are  
Y1-03-0138V  
5
 
   
standard "F" type television connectors. The connector on the back of  
the Point Pad™ is located in the center of the panel for ease of  
installation. After the coax cable has been routed and the “F”  
connectors attached to the coax cable, simply screw the “F”  
connectors to the Master Controller and the Point Pad™. The cable  
and connectors are available either through ACR Electronics, your  
local Radio Shack or other sources of electronic hardware.  
Additional Point Pads™ (up to three (3) Pads) may be used with one  
(1) Master Controller. A standard "T" connector or RG-59 television  
type "splitter" is used for each additional Point Pad(see Figure 2).  
Limit the total length of all coax cable used to 300 feet.  
The URP-102 Point Pad™ is backwards compatible with all RCL-  
100/50 Searchlights and with the URC-101 Master Controller.  
NOTE: The URP-102 Point Pad™ is not recommended for use with  
the first generation URC-100 Master Controllers.  
Y1-03-0138V  
6
 
URC-102  
Master  
URC-102  
Master  
Controller Unit  
Controller Unit  
RG-59 Coaxial Cable  
RG-59 Coaxial Cable  
Fuse  
Fuse  
“T” Conn.  
or Splitter  
URP-102  
Point Pad  
RG-59 Coaxial Cable  
Power  
Source  
Power  
Source  
URP-102  
Point Pad  
RG-59 Coaxial Cable  
URP-102  
Point Pad  
Single Point Pad  
Multiple Point Pads  
Figure 2 - Point Pad™ Connection Block Diagram  
Y1-03-0138V  
7
 
Figure 3 - URP-102 Point Pad™ Functions  
URP-102 Point Pad Functions  
Press the ON/OFF button to turn the lights ON or OFF.  
Press the SPEED button to toggle between High and Low rotation  
speeds.  
Press the Right or Left Arrows to rotate the Searchlight in that  
direction.  
Press the Up or Down Arrows to raise or lower the Searchlight-  
beam.  
To activate the XRCiZfeature, press and hold the ON/OFF  
button for greater than 5 seconds. The green LED indicates XRCiZ™  
feature is enabled.  
To deactivate the XRCiZfeature, Press and hold the ON/OFF  
button for greater than 5 seconds. The red LED indicates XRCiZ™  
feature is disabled.  
An LED blinking red / green indicates that the XRCiZfeature is  
now “exercising” the Searchlight.  
NOTE: XRCiZfeature is only available when paired with a URC-  
102 Master Controller.  
Y1-03-0138V  
8
 
Figure 4 - URP-102 Point Pad™ Surface Mount Case  
Figure 5 - URP-102 Point Pad™ Flush Mount Case  
Y1-03-0138V  
9
 
Figure 6 - URP-102 Point Pad™  
Surface Mount Case with gasket and Flush Mount Case with  
gasket  
SECTION 6 - URC-102 MASTER CONTROLLER  
Mounting  
The Master Controller can be mounted in any position near the  
Searchlight that is protected from the weather. Check in advance that  
the coax cable from the Point Pad™ and the wiring harness from the  
Searchlight can be routed to this location. Mount the Master controller  
with the wires and coax facing down. Use an appropriate fastener for  
your mounting location. Use a sealant in fastener holes to prevent  
moisture intrusion.  
General Wiring Scheme  
The RCL-100 has a unique wiring scheme. Special attention must be  
paid to the following chart. The Master Controller is supplied with an  
in-line fuse-holder on the Orange power lead. Use only 15 amp fuses  
in this fuse-holder. See Figure 9 for the Master Controller wiring  
diagram.  
WARNING: Failure to follow this arrangement may damage  
components.  
Y1-03-0138V  
10  
 
 
Master  
Searchlight  
Power Source  
Lead  
Function  
Controller Wire Cable Wire  
Orange  
+12 VDC or +24  
VDC**  
Power  
Blue  
Ground  
Ground  
Lamp Power  
Lamp Ground  
Up  
Yellow  
Green  
Red  
Yellow  
Green  
Red  
White  
Black  
Brown  
White  
Black  
Brown  
Down  
Right  
Left  
Table 1  
WARNING: This wire MUST be fused with a 15 amp fuse in the  
Master Controller's in-line fuse-holder.  
Wiring to Searchlight  
The RCL-100 Searchlight is supplied with a 15 foot integral wire  
harness. This wire harness is cut to this length specifically to allow for  
a voltage drop. Shortening the harness will decrease the life of the  
bulbs. Any extra length of wire harness should be loosely coiled in a  
convenient place. For best performance, the controller should be  
attached to the end of the 15' Searchlight wire harness. If you must  
lengthen the wire harness, use heavy duty wire to minimize the  
voltage drop. This is especially important for the YELLOW lamp  
power and GREEN lamp ground wires.  
Following the wiring scheme shown in Table 1 use the supplied butt  
connectors to connect the Master Controller to the Searchlight.  
Wiring to Point Pad™  
The RG-59 Coax cable is supplied without the “F” connectors  
attached for ease of routing. After the coax has been routed, strip the  
insulation and crimp the “F” connectors in place. Screw the “F”  
connectors to the Master Controller and the Point Pad™.  
Wiring to Power Supply  
The power source must be a fused 12 VDC, 10-amp supply or 24  
VDC, 5-amp supply. Following the wiring scheme in Table 1, use the  
supplied butt connectors to connect the Master Controller to the  
Power Source. Refer to Table 2 for proper wire size for connection of  
the input power lines.  
Y1-03-0138V  
11  
 
NOTE: As per the wiring scheme, the ORANGE wire is connected to  
the Positive terminal and the BLUE wire is connected to the Negative  
terminal of the power source.  
CAUTION: Observe polarities when attaching wires!  
Maximum Cable Length  
Wire Size  
#8 AWG  
12v System  
25 ft.  
24v System  
100 ft.  
#10 AWG  
#12 AWG  
15 ft.  
10 ft.  
60 ft.  
40 ft.  
Table 2  
Function  
The URC-102 Master Controller is designed to perform up to six  
different duties on searchlights, winches, and other electrical devices.  
The Master Controller provides optimum voltage to ensure brightest  
performance and long lamp life, regardless of boat system voltage  
fluctuations. The Master Controller is compatible with devices  
requiring 12 VDC or 24 VDC operation.  
The URC-102 Master Controller has the unique XRCiZfeature. The  
XRCiZfeature routinely operates all moving parts in the Searchlight  
to keep the motors and drive mechanism freely running. Once  
activated, and every 30 days thereafter, the XRCiZfeature wakes  
up and operates the Searchlight. The Searchlight will rotate 360in  
both directions and the parabolic reflectors will move to the full up and  
down positions. This feature keeps the Searchlight in peak working  
order when not in service for long periods of time.  
To activate the XRCiZ™ feature, press and hold the Point Pad™  
ON/OFF button for greater than 5 seconds. The green LED on the  
URC-102 Point Pad™ indicates that the XRCiZ™ feature is enabled.  
While enabled, The XRCiZfeature can be started outside of its 30-  
day cycle by pressing and holding the Speed button on the Point  
Pad™ for greater than 5 seconds.  
While the XRCiZfeature is operating the Searchlight, pressing any  
Point Pad™ button will stop the current cycle and leave the  
Searchlight to follow any additional commands.  
Y1-03-0138V  
12  
 
To deactivate the XRCiZ™ feature, press and hold the Point Pad™  
ON/OFF button for greater than 5 seconds. The Red LED on the  
URC-102 Point Pad™ indicates that the XRCiZ™ feature is disabled.  
NOTE: LED feedback is not available when using RCL-100 or URC-  
101 Point Pads™.  
NOTE: The Searchlight should not be covered while the XRCiZ™  
feature is enabled.  
The URC-102 Master Controller provides optimum voltage to ensure  
the brightest searchlight performance and long bulb life. Also to  
extend lamp life, the Master Controller has a timed lamp power up  
feature. The searchlight lamps reach full intensity within 2 seconds.  
The URC-102 Master Controller has a searchlight motor timeout  
feature. If a Point Pad™ rotation switch (right or left) is continuously  
engaged for more than 50 seconds, the Master Controller will  
interrupt the operation until the Point Pad™ switch is disengaged.  
This feature will save the searchlight motor from burnout due to  
accidental activation. The elevation motor has similar features which  
will timeout in approximately 20 seconds.  
Y1-03-0138V  
13  
 
Power Source Fuse  
12 VDC or  
24 VDC  
Spotlight  
Master Controller  
in-line 15 amp fuse  
Ground  
Blue  
Orange  
Yellow  
Green  
Red  
Lamp Power  
Lamp Ground  
Spot Up  
White  
Brown  
Black  
Spot Down  
Spot Left  
Master  
Spot Right  
75 ohm TV Coaxial Cable  
“T” Connector or Optional  
75 Ohm Splitter for Multiple  
RCL-100 Point Pads  
Other RCL-100 Point Pads  
75 ohm TV Coaxial Cable  
RCL-100  
Point Pad  
Note: Wiring must be in accordance with this diagram. Improper wiring will damage components.  
Figure 7 - URC-102 Master Controller Wiring Diagram  
Y1-03-0138V  
14  
 
Figure 8 - URC-102 Master Controller  
Y1-03-0138V  
15  
 
APPENDIX A - RCL-100D SPECIFICATIONS (with  
URC-102 Controller)  
Specification  
12V Unit  
4in (10.16cm) X  
2.75in (6.99cm)  
12- 16 VDC  
10  
24V Unit  
4in (10.16cm) X  
2.75in (6.99cm)  
24- 31 VDC  
5
Mirror diameter  
Rated voltage (Volt)  
Rated current (A)  
55W halogen  
Lamp X 2  
70W halogen  
Lamp X2  
Applicable lamp  
(base G6.35)  
JCD12V-55WDX  
(base G6.35)  
JDC24V-55WDX  
Peak beam candle  
power (candela)  
Beam spread  
(degrees)  
200,000  
160,000  
Horizontal 7°,  
Horizontal 7°,  
Vertical 5°  
Vertical 5°  
Elevation angle  
(degrees)  
Up 9°, Down 17°  
360°  
Up 9°, Down 17°  
360°  
Turning angle  
(degrees)  
per second  
Fast 28° per second,  
Slow 15° per second  
7.15lbs (3.24 kg)  
15ft (4.57M)  
6° per second  
Fast 28° per second,  
Slow 15° per second  
7.15lbs (3.24 kg)  
15ft (4.57M)  
Elevation speed  
Turning speed  
Weight  
Interconnect cable  
*All specifications are nominal values  
Y1-03-0138V  
16  
 
 
APPENDIX B - USER REPLACEABLE PARTS  
ACR/RCL-100D  
Figure 9 - Searchlight User Replaceable Parts  
Item  
Number  
ACR Part  
Number  
Description  
Quantity  
1
2
3A  
3B  
3C  
4
5
6
7
8A  
Front Glass  
Front Frame  
Window Weather Strip  
Screw M4x18  
Washer M408  
Gasket of front frame  
10 cm reflector  
1
1
1
2
2
1
2
1
1
2
HRMK 1300  
HRMK 2101  
HRMK 1201  
HRMK 1600  
HRMK 9301  
HRMK 2200  
HRMK 1301  
HRMK 2102  
HRMK 2202  
6001  
Protection Cover  
O-Ring #594  
55W quartz halogen bulb (12V)  
6003  
8B  
55W quartz halogen bulb (24V)  
2
A1-05-0660-24  
9
10  
11  
Shoulder Washer  
Base Housing  
Head Housing  
4
1
1
HRMK 2103  
HRMK 2100  
Y1-03-0138U  
17  
 
 
APPENDIX C - BULB REPLACEMENT PROCEDURE  
Two 55W, quartz-halogen bulbs are provided with your RCL-100D. If  
they should need replacement, they can be ordered through an ACR  
dealer or through ACR Electronics. The part numbers are P/N 6001 for  
12V units and P/N 6003 for 24V units.  
CAUTION: Failure to follow replacement instructions carefully can  
result in damage to bulb and/or light. All part sales are final.  
To replace the lamps:  
1. Disconnect unit from power source and allow bulbs to cool.  
2. Remove two screws holding the front flange and glass in place.  
3. To remove the old lamp bulbs, grasp base of the lamp and pull  
straight out.  
WARNING: Do not touch glass parabolic reflector with fingers or  
tools!  
4. Install the new lamp bulb using a soft clean cloth to avoid touching  
the bulb with your fingers. Insert the lamp bulb pins into socket and  
press firmly in place.  
CAUTION: If the lamp bulbs or reflectors are accidentally touched,  
carefully clean with a soft rag and alcohol (isopropanol) before  
continuing.  
5. Replace the front flange and glass and install the two retaining  
screws. Be sure the neoprene gasket is securely in place.  
6. Reconnect the unit to the power source.  
Y1-03-0138V18  
 
APPENDIX D - PRODUCT COMPONENTS  
Product No. 1930.3 - RCL-100D 12 V Searchlight Installation Kit  
includes:  
Description  
Searchlight, RCL-100D, 12 V  
Kit, Nylon Washers (4)  
Quantity  
ACR Part Number  
A3-06-1106-3  
A3-06-1940  
1
1
Connector, “F”  
2
15ft  
1
A1-03-0220  
A2-07-0002-6  
A3-06-2231  
A1-03-0222  
A3-06-2230  
Cable, Coaxial  
Master Controller, URC-102  
Connector, "In-Line"  
8
Point Pad™, URP-102 with  
1
Surface Mount Case  
Case, Flush Mount  
Gasket, Surface Mount  
Gasket, Flush Mount  
U Clamp  
1
1
1
2
2
A1-18-1875-2  
A1-25-0140-1  
A1-25-0140-2  
A1-17-1366  
Nuts, Nylon-lock  
A1-05-0776  
Washers  
Warranty Card  
2
1
A1-05-0777  
A1-20-1019  
Product Support Manual  
Mounting Templates  
1
1
Y1-03-0138  
Y1-03-0138-1  
Product No. 1931.3 - RCL-100D 24 V Searchlight Installation Kit  
includes:  
Description  
Searchlight, RCL-100D, 24 V  
Kit, Nylon Washers (4)  
Quantity  
ACR Part Number  
A3-06-1106-4  
A3-06-1940  
1
1
Connector, “F”  
2
15ft  
1
A1-03-0220  
A2-07-0002-6  
A3-06-2231  
A1-03-0222  
A3-06-2230  
Cable, Coaxial  
Master Controller, URC-102  
Connector, "In-Line"  
8
Point Pad™, URP-102 with  
1
Surface Mount Case  
Case, Flush Mount  
Gasket, Surface Mount  
Gasket, Flush Mount  
U Clamp  
1
1
1
2
2
A1-18-1875-2  
A1-25-0140-1  
A1-25-0140-2  
A1-17-1366  
Nuts, Nylon-lock  
A1-05-0776  
Washers  
Warranty Card  
2
1
A1-05-0777  
A1-20-1019  
Product Support Manual  
Mounting Templates  
1
1
Y1-03-0138  
Y1-03-0138-1  
Y1-03-0138V19  
 
APPENDIX E - ACCESSORY COMPONENTS  
Product No. 1927.3 - URC-102 Master Controller Installation Kit  
includes:  
Description  
Quantity  
ACR Part Number  
Master Controller, URC-102  
1
A3-06-2231  
Connector, "In-Line"  
8
1
A1-03-0222  
Y1-06-0178  
Instruction  
Controller  
Sheet,  
Master  
Product No. 1928.3 - URP-102 Point Pad™ Installation Kit includes:  
Description  
Point Pad™, URP-102 with  
Surface Mount Case  
Quantity  
ACR Part Number  
A3-06-2230  
1
Case, Flush Mount  
1
1
1
2
2
2
1
1
1
1
A1-18-1875-2  
A1-25-0140-1  
A1-25-0140-2  
A1-17-1366  
A1-05-0776  
A1-05-0777  
A1-18-1871  
A1-18-1892  
Y1-06-0179  
Y1-03-0138-1  
Gasket, Surface Mount  
Gasket, Flush Mount  
U Clamp  
Nuts, Nylon-lock  
Washers  
Adapter Plate, Flush mount  
Adapter Plate, Surface mount  
Instruction Sheet, Point Pad™  
Mounting Templates  
Product No. 1929.1 - Wiring Kit RCL-50 / 100 series searchlights  
includes:  
Description  
Connector, “F”  
Cable, Coaxial  
Quantity  
ACR Part Number  
A1-03-0220  
2
15ft  
A2-07-0002-6  
Y1-03-0138V20  
 
Product No. 9282.3 URP-102 Point Pad™ Secondary Station  
Installation Kit includes:  
Description  
Quantity  
ACR Part Number  
Point Pad™, URP-102 with  
Surface Mount case  
1
A3-06-2230  
Case, Flush Mount  
Gasket, Surface Mount  
Gasket, Flush Mount  
U Clamp  
1
1
A1-18-1875-2  
A1-25-0140-1  
A1-25-0140-2  
A1-17-1366  
A1-05-0776  
A1-05-0777  
A1-18-1871  
A1-18-1892  
A1-03-0235  
A1-05-0614  
A2-07-0002-6  
A1-03-0220  
Y1-06-0179  
Y1-03-0138-1  
1
2
Nuts, Nylon-lock  
2
Washers  
2
Adapter Plate, Flush mount  
Adapter Plate, Surface mount  
Splitter, 2-Way Signal  
Screw, #6  
1
1
1
2
Cable, Coaxial  
15ft  
4
Connector, "F"  
Instruction Sheet, Point Pad™  
Mounting Templates  
1
1
Product No. 9283.3 Remote Control Installation Kit Includes:  
Description  
Quantity  
ACR Part Number  
Master Controller, URC-102  
1
A3-06-2231  
Connector, "In-Line"  
8
1
A1-03-0222  
A3-06-2230  
Point Pad™, URP-102 with  
Surface Mount Case  
Case, Flush Mount  
Gasket, Surface Mount  
Gasket, Flush Mount  
U Clamp  
1
1
A1-18-1875-2  
A1-25-0140-1  
A1-25-0140-2  
A1-17-1366  
A1-05-0776  
A1-05-0777  
A1-18-1871  
A1-18-1892  
A2-07-0002-6  
A1-03-0220  
Y1-06-0178  
1
2
Nuts, Nylon-lock  
2
Washers  
2
Adapter Plate, Flush mount  
Adapter Plate, Surface mount  
Cable, Coaxial  
1
1
15ft  
2
Connector, "F"  
Instruction  
Controller  
Sheet,  
Master  
1
Instruction Sheet, Point Pad™  
1
1
Y1-06-0179  
Y1-03-0138  
Mounting Templates  
Y1-03-0138V21  
APPENDIX F - WARRANTY, NOTICES  
Limited Warranty  
This product is warranted against factory defects in material and workmanship  
for a period of 1 (one) year* from date of purchase or receipt as a gift. During  
the warranty period ACR Electronics, Inc. will repair or, at its option, replace the  
unit at no cost to you for labor, materials and return transportation from ACR.  
For further assistance, please contact our Technical Service Department at ACR  
Electronics, Inc., 5757 Ravenswood Road, Fort Lauderdale, FL 33312-6645.  
Email: [email protected], Fax: +1 (954) 983-5087, Telephone: +1 (954)  
981-3333.  
This warranty does not apply if the product has been damaged by accident or  
misuse, or as a result of service or modification performed by an unauthorized  
factory. Except as otherwise expressly stated in the previous paragraph, THE  
COMPANY MAKES NO REPRESENTATION OR WARRANTY OF ANY KIND,  
EXPRESS OR IMPLIED, AS TO MERCHANTABILITY, FITNESS FOR A  
PARTICULAR PURPOSE, OR ANY OTHER MATTER WITH RESPECT TO  
THIS PRODUCT. The Company shall not be liable for consequential or special  
damages.To place the warranty in effect, register online at www.acrartex.com or  
return the attached card within 10 days.  
*Five years for the following products: EPIRB, PLB, S-VDR, SSAS.  
Notices  
ACR Electronics diligently works to provide a high quality Product Support  
Manual, however, despite best efforts, information is subject to change without  
notice, and omissions and inaccuracies are possible. ACR cannot accept liability  
for manual contents. To ensure that you have the most recent version of the  
Product Support Manual, please visit the ACR website at www.acrartex.com.  
©2008 by ACR Electronics, Inc. All rights reserved. Reproduction in whole or in  
part is permitted only with permission of ACR Electronics, Inc. Ongoing product  
improvements may change product specifications without notice.  
Trademarks or registered trademarks are the property of their respective  
owners.  
Y1-03-0138V22  
 
EC DECLARATION OF CONFORMITY  
ACR Electronics, Inc. hereby declares that the following product is in conformity with  
Directive 2004/108/EC of the European Parliament and of the Council of 15 December  
2004 on Electromagnetic Compatibility (EMC Directive). In accordance with the Directive,  
the product will be marked with the CE conformity marking as follows:  
Product:  
Searchlight  
Model: RCL-100D  
Regulations and  
Standards:  
EN 60945:2002: Emissions  
CISPR 16-1:1999 (Conducted Emissions)  
CISPR 16-1:1999 (Radiated Emissions)  
EN60945: 2002: Immunity:  
IEC 61000-4-2: 1995 (Electrostatic Discharge)  
IEC 61000-4-3: 1995 (Radiated Immunity)  
IEC 61000-4-4: 1995 (Immunity to Fast Transients)  
IEC 61000-4-6: 1995 (Conducted Immunity, Power and I/O Leads)  
IEC 61000-4-11: 1994 (Voltage Dips and Interrupts)  
Manufacturer:  
ACR Electronics Inc.  
5757 Ravenswood Road  
Fort Lauderdale, FL 33312  
USA  
Signed on behalf of ACR Electronics Inc.  
Signed: __________________________________________  
Name: Thomas J. Pack  
Date:  
November 11, 2010  
Title: Director, New Product Development  
Document RCL-100D-004  
This Declaration complies with  
ISO/IEC 17050-1:2004  
ACR Electronics, Inc. is registered by NQA to ISO 9001:2008  
Y1-03-0138V23  

3M Cable Box 2250M User Manual
Accusplit Fitness Electronics AE1540M2 User Manual
AEG Washer 135 EL User Manual
Aiphone Swing Sets DD UR User Manual
Alamo Lawn Mower 4837 User Manual
Alto Shaam Oven 1000 TH I User Manual
AMX Switch RDM 2SWM User Manual
Aspire Digital Computer Accessories T130 User Manual
Audiovox Car Stereo System AVDINPC User Manual
Axis Communications Security Camera P5415E User Manual