Quick Installation Guide
For the 3Com Switch 4007R 8-slot Chassis
Part No. 10014099
Published February 2002
Quick Installation Guide
Read this document before you attempt to install the 3Com Switch
■
■
■
■
■
Switch Setup Tasks
Unpacking Instructions
Preinstallation Guidelines
Installing the Mounting Shelves
Installing the Chassis
Switch 4007R Kits
The Switch 4007R is available as a starter kit as described below:
3Com Gigabit Layer 2 Starter Kit (3C16817)
■
■
■
■
■
■
8-slot chassis (3C16804)
820W AC Power Supply (3CB9EP8)
Management Module (3CB9EME)
24-Gigabit Ethernet Fabric (3CB9FG24T)
2 of 9-port 1000BASE-SX Module (3CB9LG9MC)
■
3Com Gigabit Layer 3 Starter Kit (3C16818)
■
■
■
■
■
■
8-slot chassis (3C16804)
820W AC Power Supply (3CB9EP8)
Management Module (3CB9EME)
24-Gigabit Ethernet Fabric (3CB9FG24T)
9-port 1000BASE-SX Module (3CB9LG9MC)
4-port Gigabit Multilayer Switch Module (GBIC) (3CB9RG4)
2
Quick Installation Guide
This guide is intended for the system or network administrator who is
responsible for installing and managing the network hardware.
WARNING: The Switch 4007R chassis must be installed, removed, or
replaced only by trained service personnel. Do not attempt to install,
remove, or replace a Switch 4007R chassis if you have not had the proper
training from 3Com.
WARNING: You can install the Switch 4007R chassis on a table, a shelf,
or a rack. To minimize the risk of personal injury or equipment damage,
3Com recommends that at least two people perform an installation.
Figure 1 3Com Switch 4007R 8-slot Chassis
Switch fabric
module slots
Interface
module slots
Management
module slots
R
Switch
4007
1
2
3
4
5
6
7
8
9
10
ON
Power supply slots
Quick Installation Guide
3
Switch Setup Tasks Figure 2 illustrates the tasks to perform to set up a Switch 4007R 8-slot
chassis.
Figure 2 Setup Tasks for Switch 4007R 8-slot Chassis
Determine Site Requirements
• Enterprise Switch Getting Started
Guide, Appendix B
Administer and Operate
the Switch
Unpack the Switch 4007
Chassis
1
• “Unpacking Instructions”
(On the shipping box and
in this guide)
• Enterprise Management Engine
User Guide, Chapter 4 and
Chapter 5
12
2
Troubleshoot Problems
• Enterprise Management Engine
User Guide, Chapter 8
Install the Universal Mounting
Shelf (for a rack installation)
•
Quick Installation Guide for
the 8-slot Chassis (this guide)
R
Switch 4007
1
2
3
4
5
6
7
8
9
10
11
3
4
5
Configure the Switch for
Management
• Enterprise Management Engine
User Guide, Chapter 4 and
Chapter 5
Install the Chassis and
Optional Devices
•
Quick Installation Guide for
the 8-slot Chassis (this guide)
10
ON
Power On the Switch
• Enterprise Switch Getting Started
Guide, Chapter 5
Install a Power Supply and
the Power Cable
• Power Supply Installation Guide
Switch 4007 8-slot Chassis
for the 8-slot Chassis
9
Install Interface Modules
• Interface module quick start or
getting started guides
• Interface module user guides
(if available)
Install an EME Management
Module
• Enterprise Management Engine
Quick Start Guide
• Enterprise Management Engine
User Guide
8
6
Install a Switch Fabric
Module
• Switch fabric module quick
start or getting started guides
• Switch fabric module
user guides (if available)
7
4
Quick Installation Guide
Unpacking Follow these steps:
Instructions
1 Place the chassis shipping box near the rack, the table, or the shelf where
you plan to install the chassis.
WARNING: Safety regulations state that the selected table, shelf, or rack
must be able to support at least three times the weight of a fully loaded
chassis.
■
A fully loaded 8-slot chassis weighs approximately 71.7 kg (158 lb).
Therefore, the selected table, shelf, or rack must support at least
215.1 kg (474 lb).
2 Cut the tape that covers the seam on the top of the box.
3 Remove the following items (Figure 3) from the top of the shipping box:
■
One hardware kit in a plastic bag (Part Number 10002489 16SL HDW)
■
Four plastic feet to mount to the bottom of the chassis (for a
tabletop installation)
■
■
■
Four 6-32 Phillips-head screws to mount the feet
Twelve rack-mount clips for a rack-mount installation
Twelve 10-32 Phillips-head screws to attach the chassis to the rack
■
One plastic label bezel to snap into the top front of the 8-slot chassis
NOTE: To prevent the plastic label bezel from being damaged, do not
attach it to the chassis until after you have installed all components into
the chassis and you are ready to power on the Switch.
■
Two universal mounting shelves (brackets)
One documentation kit that contains:
■
■
Documentation CD-ROM
■
Chassis Quick Installation Guide for the Switch 4007R 8-slot
Chassis
■
■
■
Switch 4007R Getting Started Guide
Switch 4007 Web Management User Guide
Power Supply Installation Guide for the Switch 4007R
Quick Installation Guide
5
Figure 3 Contents of the Switch 4007R Chassis Shipping Box
Chassis Top
Chassis rack-mount template
Plastic label bezel
Switch
4007
Pre-installed
pin
2 Mounting shelves
Documentation
CD-ROM
Plastic feet
6-32 screws
10-32 screws
Rack-mount clips
Pre-installed
pin
1000XXXX
HARD
W
ARE KIT
Mounting
shelf
Chassis Bottom
Plastic bag for
hardware kit
Rack hole
6
Quick Installation Guide
4 Remove the top foam packing material (Figure 4).
Figure 4 Removing the Chassis Shipping Box
Top foam
packing material
Corrugated sleeve
Bottom foam
packing material
Shipping skid
5 On the outside of the shipping box on the skid, cut the shipping bands.
6 Remove the corrugated sleeve by pulling it straight up (Figure 4).
The 8-slot chassis is shipped with module slot 1, slot 7; management
module slot 9 empty. No blank faceplate covers these slots. See Figure 5.
Quick Installation Guide
7
Figure 5 The Switch 4007R 8-slot Chassis is Shipped with These Slots Empty
Switch fabric
module slot 7
Interface
module
slot 1
Management
module slot 9
R
Switch
4007
1
2
3
4
5
6
7
8
9
10
ON
Power supply slots
After you receive the chassis, remove the faceplate from power supply
slot 3 to help make chassis installation easier. See step 8 in this section.
7 While the 8-slot chassis is still in the base of the shipping box, have one
person grasp the chassis and tilt the chassis backward.
8 To make chassis installation easier, remove another blank faceplate from a
power supply slot.While the 8-slot chassis is in this position, and using a
flat-blade screwdriver, remove the blank faceplate from power supply slot
3 only.
9 Using two people, lift the Switch 4007R 8-slot chassis out of the shipping
box base and place the chassis on the floor in front of the rack, table, or
8
Quick Installation Guide
shelf that you plan to use. To help you hold onto the 8-slot chassis when
you lift it, you can place one hand into the empty power supply slot 3.
The other person places one hand into empty power supply slot 1.
10 Inspect the chassis for damage. If the chassis appears to be damaged,
repack it in the shipping box and contact your local supplier.
The shipping box is reusable; place all packing materials in the chassis
shipping box and store the shipping box for future use.
Preinstallation This section provides safety precautions, installation guidelines, and
Guidelines location requirements to help you install the Switch 4007R 8-slot chassis
into your environment.
Safety Precautions
Read this section before you install the Switch 4007R 8-slot chassis.
WARNING: The rack-mount installation requires at least two people. Do
not attempt to install the chassis alone. To reduce the possibility of
personal injury or serious damage to the chassis when you install the
chassis into a rack, first install the mounting shelves that are shipped with
your chassis. The mounting shelves help hold the chassis in place while
you secure the chassis to the rack. Rest the chassis on the mounting
shelves and continue to support the chassis until after you have securely
installed at least four of the eight screws (two screws per rack-mount
flange) for the chassis.
If you do not use the mounting shelves and then you attempt to place the
weight of the rack-mounted chassis on fewer than four fully installed
screws, the chassis may drop off of the rack. Personal injury or serious
damage to the chassis may result. The tabletop or shelf installation also
requires at least two people to lift the chassis onto the table or shelf.
WARNING: The chassis has two stationary, preinstalled flange pins
located in the Telco rack slot. Use these flange pins only to help position
the chassis. Do not use these pins to support the full weight of the
chassis.
WARNING: When the Switch 4007R 8-slot chassis is fully loaded with
modules and load-sharing power supplies, the chassis weighs
approximately 71.7 kg (158 lb). Therefore, for a rack installation, install
the mounting shelves and then your 8-slot chassis before you install
modules and power supplies.
Quick Installation Guide
9
WARNING: Safety regulations state that the selected table, shelf, or rack
must be able to support at least three times the weight of a fully loaded
chassis.
■
A fully loaded 8-slot chassis weighs approximately 71.7 kg (158 lb).
Therefore, the selected table, shelf, or rack must support at least
215.1 kg (474 lb).
WARNING: To ensure mechanical stability and to avoid circuit
overloading and improper grounding, follow the rack manufacturer’s
instructions for rack installation. If the instructions are unclear, consult a
qualified electrician.
Location Requirements
Install a Switch 4007R 8-slot chassis in an area that meets the following
requirements:
■
■
■
Ambient (room) temperature is from 0 °C to 50 °C (32 °F to 122 °F).
Relative humidity is between 10 and 90 percent, noncondensing.
The table, shelf, or rack on which you mount the chassis supports at
least three times the weight of a fully loaded chassis.
■
■
■
■
■
There is at least 91.4 cm (36 in.) in back of the chassis to remove and
replace fan trays and to ensure proper cooling in the chassis.
The power source is within approximately 2 meters (6.6 feet) of the
location where you plan to install the Switch 4007R.
Each of the power supplies connects to a dedicated socket. Do not
connect the power supplies to a power strip.
For a tabletop or shelf installation, the surface on which you want to
locate the Switch 4007R chassis is level.
For rack installations, the selected rack is grounded in accordance with
the rack manufacturer’s recommendations.
Before You Begin
Before you install the 8-slot chassis:
■
Move the Switch 4007R chassis close to where you plan to install it.
Place the chassis in front of the rack, table, or shelf that you plan to
use.
■
For a rack installation, make certain that you have a Phillips
screwdriver and a flat-blade screwdriver, the two mounting shelves,
10
Quick Installation Guide
and the 12 screws (from the hardware kit) available when you begin
to install the chassis.
■
For a tabletop or shelf installation, make certain that you have a
Phillips screwdriver or flat-blade screwdriver and the hardware kit
available.
Before you attempt to mount the chassis in a rack, use the following
rack-mount installation guidelines to ensure your safety and optimal
performance. Review the guidelines before you install the chassis in a
rack.
■
Because the equipment rack environment can cause increased
ambient temperatures and reduced air flow, review the chassis
specifications and site requirements in Appendix A and Appendix B of
the Switch 4007R Getting Started Guide.
Figure 6 shows two types of racks that you can use.
Figure 6 Rack Types
1 Bolt the rack to the floor.
2 Brace the top of the rack against the wall. Make certain that the rack is
properly aligned and squared. Use a framing tool to ensure that the rack
is squared.
Quick Installation Guide
11
3 To help support the chassis while you install it in a rack, install the
mounting shelves that are shipped with your chassis. If you install more
than one chassis in a rack, install the bottom chassis first. Make certain
that there is sufficient space between the bottom chassis and the top
chassis to provide space for an optional cable management device.
4 Position the rack-mount clips if you are going to use them for the
rack-mount installation. If you install the chassis in Metric rack slots,
install the clip nuts and screws in the closed slots of the rack-mount
flanges. If you install the chassis in Telco rack slots, position the chassis
and then install the screws and rack-mount clips in the open slots.
If you want to use an optional cable management device, install it above
or below the chassis (depending on which type of device you choose).
You can install the chassis in the rack either before or after you install a
cable management device.
Use the following guidelines to tighten screws to Torque Specification:
■
Faceplate thumbscrews — 5-7 in/lb (inch-pounds)
■
rack rail — 22-25 in/lb
To ensure that you tighten screws to Torque Specification, use a torque
screwdriver.
Selecting the Slot on the Rack
The 8-slot chassis have two slot types on the rack-mount flanges to
mount the chassis in a rack. Figure 7 shows the Telco and Metric slots and
the location of the preinstalled rack-mount flange on the 8-slot chassis.
12
Quick Installation Guide
Figure 7 Preinstalled Rack-mount Flange Location and Slot Types on the Switch
4007R 8-slot Chassis
Switch 4007
Preinstalled
flange pin
Telco rack
open slot
Metric rack
closed slot
Using the Chassis Rack-mount Template
Use the paper rack-mount chassis template (which is an accurate copy of
the chassis rack-mount flange) to help you position the mounting shelves
and the Switch 4007R chassis when you install them into a rack. See
Figure 2. The chassis rack-mount template is designed for use with:
■
Racks that have rack slot hole distances as shown in Figure 8. Your
rack can have either round or square rack slot holes.
■
Telco (open) rack slots.
Installing the The 8-slot chassis are shipped with two mounting shelves and screws.
Mounting Shelves Install one mounting shelf on each side of the rack. The top slot on the
mounting shelf is equipped with an alignment pin to help you insert and
position the mounting shelf in the rack.
CAUTION: On some racks, the mounting shelf may not align easily to
install the two mounting shelf screws. One screw per mounting shelf can
support an empty chassis. However, make certain to secure the chassis to
the rack before you add any other components.
The use of clip nuts is optional.
Quick Installation Guide
13
To install the mounting shelves, follow these steps:
1 Obtain the chassis rack-mount template, two mounting shelves, four
screws, and four clip nuts (optional) that you received in the shipping box.
2 Locate where you want to install the mounting shelves.
a While you hold the chassis rack-mount template in place, locate the
slots on each rack rail to mount the shelves.
b Mark the desired positions on the rack.
The rack has a series of paired and single slots that are positioned with
specific distances between each slot (Figure 8).
Figure 8 Slots on the Rack and Distances Between Each Slot
Alignment pin
position
1/2"
5/8"
5/8"
Paired slot
Single slot
1/2"
5/8"
5/8"
1/2"
5/8"
5/8"
1/2"
3 Insert a mounting shelf in the rack.
a Select the desired rack slot position, using the top slot of a pair of slots
for the mounting shelf alignment pin (Figure 9).
b Slide the two clip nuts onto the selected rack slot position (optional).
14
Quick Installation Guide
c Insert the alignment pin (Figure 9) into the rack slot.
If the rack you are using to install the chassis is not threaded, apply
pressure and push up on the mounting shelf to align the hole properly
with the rack slot hole. The alignment pin on the mounting shelf will then
insert easily into the rack.
4 Using a Phillips screwdriver or flat-blade screwdriver, insert the two
screws and tighten (Figure 9).
Figure 9 Installing a Mounting Shelf into the Rack
Rack
Preinstalled
alignment pin
Preinstalled
alignment pin
Screws
Mounting
shelf
5 Repeat steps 3 and 4 to mount the other shelf on the opposite rack rail.
Make certain that the mounting shelf is aligned to the same rack slot
positions on both sides of the rack.
Quick Installation Guide
15
Installing the Chassis This section describes how to install the chassis:
■
■
■
In a rack without clip nuts
In a rack with clip nuts
On a table or a shelf
You may have other types of racks at your site. Follow the manufacturer’s
suggested installation procedures.
Before you begin, examine the rack to determine if you need to use clip
nuts in this installation.
Installing the Chassis in a Rack Without Clip Nuts
Follow these steps to mount the 8-slot chassis in a rack. Use at least two
people to perform this installation.
You have already installed the mounting shelves into the rack and you
have the rack-mount screws and a Phillips screwdriver or flat-blade
screwdriver available.
To prevent the plastic label bezel from being damaged, do not attach it to
the chassis until after you have installed all components into the chassis
and you are ready to power on the Switch.
1 Obtain the chassis rack-mount template that you received in the shipping
box.
2 Align the template to match the slots of one of the mounting shelves.
3 While you hold the template in place, locate the holes on the rack where
you want to place the chassis. Make certain that the holes on the
template match up with the rack slot holes.
4 Locate and mark the holes on the rack, at the top and the bottom where
you want to place the chassis and the screws.
5 Prepare to lift the chassis.
a Standing on one side of the chassis, one person places a left hand in
power supply slot 3 and with the right hand grasps the handle at the
top rear of the chassis.
b The other person, who is standing on the opposite side of the chassis,
places a right hand in power supply slot 1 and with the left hand
grasps the handle on the top rear of the chassis.
16
Quick Installation Guide
6 Two people lift the chassis through the front of the rack and onto the
mounting shelves. Continue to support the chassis until after you have
securely installed at least four of the eight screws (two screws per
rack-mount flange) for the chassis.
7 Slide the chassis into the rack, using the mounting shelves for support,
until both rack-mount flanges are flush with the front of the rack.
Use the preinstalled flange pins in the Telco rack slot to position the
chassis at the desired slot position in the rack.
WARNING: Support the back of the chassis until the two bottom screws
are fully inserted.
8 While the chassis rests on the mounting shelves and you support the
chassis, insert one bottom screw on each side of the chassis and then
tighten the screw.
Tighten the #10 screws that hold the chassis onto the rail to a Torque
Specification of 22-25 in/lb (inch-pounds).
9 Insert one top screw on each side of the chassis and then tighten the
screw.
10 Install all remaining screws and tighten them.
11 Attach the plastic label bezel to the 8-slot chassis.
a With both hands, grasp the plastic label bezel and face the front of
the chassis.
b Snap the plastic label bezel onto the top front of the chassis to secure
it.
Installing the Chassis in a Rack Using Rack-Mount Clip Nuts
Follow these steps to mount the chassis in a rack when you use
rack-mount clip nuts.
Not all racks require that you use rack-mount clips. Use whatever method
of rack-mount equipment that you have to meet installation
requirements in a rack.
Use at least two people to perform this installation.
You have already installed the mounting shelves into the rack and you
have the clip nuts with rack-mount screws and a Phillips screwdriver or
flat-blade screwdriver available.
Quick Installation Guide
17
To prevent the plastic label bezel from being damaged, do not attach it to
the chassis until after you have installed all components into the chassis
and you are ready to power on the Switch.
1 Obtain the chassis rack-mount template that you received in the shipping
box.
2 Align the template to match the slots of one of the mounting shelves.
3 While you hold the template in place, locate the holes on the rack where
you want to place the clip nuts. Make certain that the holes on the
template match up with the rack slot holes.
4 Mark the holes on the rack, at the top and the bottom where you want
to place the clip nuts and the screws.
5 Install the clip nuts on the rack in the positions that you selected. See
Figure 10.
The rack slots are not equally spaced, so align the clip nuts to the slots
properly for the screws to be easily installed.
Figure 10 Installing a Rack-mount Clip in the Rack
Rack rail
10-32 inch screw
Be sure to thread the screw
through this nut to securely
attach each clip to the rack
Top view
6 Slide the chassis into the rack, using the mounting shelves for support,
until both chassis rack-mount flanges are up against the rack. Push until
the chassis rack-mount flanges are flush with the rack.
7 Using the preinstalled flange pins for guidance, match the slots on the
rack-mount flange to each clip nut on the rack.
WARNING: Support the back of the chassis until the two bottom screws
are fully inserted.
18
Quick Installation Guide
8 Secure the chassis to the rack with the screws provided (eight 10-32 inch
screws) and with the rack-mount clips.
a Install one screw on each side in the bottom slot on each rack-mount
flange.
b Allow the weight of the chassis to rest on the mounting shelves and
install the remaining screws while you continue to support the chassis.
c Tighten all screws completely.
Tighten the #10 screws that hold the chassis onto the rail to a Torque
Specification of 22-25 in/lb (inch-pounds).
9 Attach the plastic label bezel to the chassis.
a With both hands, grasp the plastic label bezel and face the front of
the chassis.
b Snap the plastic label bezel onto the top front of the chassis to secure
it.
Installing the Chassis on a Table or Shelf
This section describes how to attach plastic feet to the chassis and how to
install the chassis on a table or a shelf.
WARNING: When you install the chassis on a table or shelf, do not use
the optional cable management device. The chassis can tip over under
certain conditions. Hardware damage or personal injury can result.
WARNING: Safety regulations state that the selected table or shelf must
be able to support at least 215.1 kg (474 lb), which is three times the
weight of a fully loaded 8-slot chassis.
Attaching the Chassis Feet To install plastic, molded feet on the
Switch 4007R chassis, follow these steps:
1 Using at least two people, prepare to lift the chassis onto the table or
shelf.
a Standing on one side of the chassis, one person places a left hand in
power supply slot 3 and with the right hand grasps the handle at the
top rear of the chassis.
b The other person, who is standing on the opposite side of the chassis,
places a right hand in power supply slot 1 and with the left hand
grasps the handle on the top rear of the chassis.
2 Two people lift the chassis onto the table or shelf.
Quick Installation Guide
19
3 Position the chassis on its side so that you can access the bottom of the
chassis.
4 Remove the four feet and the four screws from the hardware kit.
5 Using a flat-blade screwdriver, screw the feet to the bottom of the
chassis. See Figure 11.
Figure 11 Attaching Plastic Feet to the Switch 4007R Chassis
Installing the Chassis on a Table or Shelf To install the chassis on a
table or on a shelf, follow these steps:
1 Using at least two people, lift and turn the chassis upright on its installed
plastic feet.
2 Position the chassis on the table or shelf so that the chassis rests upright
squarely on the table or on the shelf (on all four feet).
3 Ensure that the front and the rear of the chassis are unobstructed and
easy to reach.
CAUTION: To prevent the plastic label bezel from being damaged, do not
attach it to the chassis until after you have installed all components into
the chassis and you are ready to power on the Switch.
4 Attach the plastic label bezel to the chassis.
a With both hands, grasp the plastic label bezel and face the front of
the chassis.
b Snap the plastic label bezel onto the top front of the chassis to secure
it.
Where to Go from To get your Switch 4007R and its components installed and configured so
Here that you can connect it to your network, follow the setup tasks shown in
20
Quick Installation Guide
Figure 2. If you need more details about each setup task, see the
indicated Switch 4007R documents.
Locating 3Com The Switch 4007R Getting Started Guide is available in Adobe Acrobat
User Documentation Portable Document Format (PDF) format on the Switch 4007R
Documentation CD-ROM.
The CD-ROM also contains:
■
Additional Switch 4007R documents in Adobe Acrobat format
Adobe Acrobat Reader and Reader installation instructions
■
If you have difficulty installing the Acrobat Reader, use an Internet
browser to download the reader from the Adobe home page at:
You can view additional 3Com technical documentation on the 3Com
home page at:
|